SUMMARY
The DTR is a kerosene-fired greenhouse heater designed to help protect crops from frost and sudden temperature drops by creating natural air circulation inside the greenhouse.
It is intended for crop protection in greenhouses rather than general room heating or whole-greenhouse space heating.
FEATURES
- Natural convection helps circulate warmer air near the crop and reduce the risk of frost damage.
- Heat output: 660 kcal/h.
- Fuel consumption: approximately 0.08 L/h.
- 4 L kerosene tank with approximately 50–60 hours of continuous burn time under reference conditions.
- White-flame combustion is intended for greenhouse crop-protection use.
IMPORTANT USE NOTES
- Greenhouse crop-protection use only: This is not intended as a general room heater or as a primary heater for warming an entire greenhouse.
- Ventilation: Ventilate the greenhouse approximately once every half day.
- Fuel: Kerosene.
- Ignition: Match ignition.

SPECIFICATIONS
| Material | Chimney top / heat-resistant steel plate (aluminized steel), tank / PP resin |
|---|---|
| Tank capacity | 4 liters |
| Continuous burn time | 50–60 hours |
| Heat output | 660 kcal/h |
| Ignition method | Match ignition |
| Fuel type | Kerosene |
| Mechanism | Wick up-down type, white flame combustion |
| Size | W250 × D250 × H660 mm |
| Weight | Approx. 1.8 kg |
| Fuel consumption | Approx. 0.08 L/h |