HORIBA Compact Sodium Ion Meter LAQUAtwin Na-11

HORIBASKU: 4540565006957
No reviews

Price:
Sale price$304.00 USD

SUMMARY

This compact sodium ion meter measures sodium ion concentration by applying a small amount of sample, from only 0.3 mL, directly to the flat sensor.

LAQUAtwin's unique planar ion-selective electrode enables quick and reliable measurement in a compact, portable format.

It is useful for food and process control, health-related sodium assessment, environmental testing, and the management of salt damage in agriculture.

FEATURES

  • Measures sodium ion concentration from only 0.3 mL of sample
  • Measurement possible from 0.05 mL when using Sampling Sheet B
  • Flat sodium ion-selective sensor with excellent selectivity
  • Wide measurement range from 2 to 9900 ppm (mg/L)
  • Up to two calibration points
  • Automatic recognition of the default 150 ppm and 2000 ppm standard solutions
  • Low- and high-concentration calibration points can be adjusted
  • Multiplication compensation from 0.01 to 9.90
  • Sodium concentration, temperature, and mV display modes
  • Temperature sensor adjustment function
  • Auto Hold function
  • Auto Stability function
  • Backlit monochrome digital LCD
  • Automatic power-off after 30 minutes
  • Remaining battery level display
  • IP67 water-resistant construction
  • Replaceable sensor
  • Portable storage case and measurement accessories included

VERSATILE SAMPLING METHODS

LAQUAtwin's flat-sensor design allows samples to be applied or collected in several convenient ways. Choose the method that suits the sample and measurement purpose.

Note: Depending on the sample, preparation such as extraction, dilution, filtration, or the addition of pure water may be required. Measurements of solid, powder, or sheet-like samples may be used as reference values unless an established sample-preparation method is followed.

Direct Drop Measurement

Apply a liquid sample directly to the flat sensor with a syringe, pipette, or dropper. The Na-11 requires at least 0.3 mL for direct measurement. Sampling Sheet B allows measurement from as little as 0.05 mL.

Applying a liquid sample directly to a LAQUAtwin sodium ion sensor

Immersion Measurement

For liquid samples in a beaker or container, the sensor can be immersed directly in the sample. Open the sliding cap on the sensor guard before measurement.

Immersing a LAQUAtwin sodium ion sensor directly in a liquid sample

Scoop Sampling

The sensor guard can be used to scoop a liquid sample directly from a river, lake, tank, process line, or other sampling location for convenient on-site measurement.

Scooping a liquid sample directly with a LAQUAtwin sodium ion meter

Moist Solid Samples

Moist solid samples such as foods can be cut into small pieces and placed directly on the flat sensor when sufficient liquid makes contact with the electrode.

Placing a moist solid sample on a LAQUAtwin sodium ion sensor

Powder Samples

Place the powder sample on the flat sensor and add a fixed amount of pure water before measurement. Keep the sample amount and water volume consistent when comparing results.

Measuring a powder sample with a LAQUAtwin sodium ion sensor

Paper, Textiles, and Sheet-like Samples

Cut paper, textiles, or other sheet-like samples into small pieces, place them on the flat sensor, and add a fixed amount of pure water before measurement.

Measuring paper textile or sheet-like samples with a LAQUAtwin sodium ion meter

SPECIFICATIONS

Model LAQUAtwin-Na-11
Measurement Principle Ion-selective electrode method
Required Sample Volume 0.3 mL or more
Measurement from 0.05 mL is possible when using Sampling Sheet B*1
Measurement Range

2 to 9900 ppm (mg/L)

0.1 to 430 mmol/L

Resolution

2 to 99 ppm: 1 ppm

100 to 990 ppm: 10 ppm

1000 to 9900 ppm: 100 ppm

Temperature Display Range / Resolution 0 to 50°C / 0.1°C
Calibration Up to 2 points
Default calibration values: 150 ppm and 2000 ppm
Accuracy ±10% of the reading*2
Main Functions

Automatic recognition of 150 ppm and 2000 ppm standard solutions

Adjustable low- and high-concentration calibration points

Multiplication compensation: 0.01 to 9.90

Sodium concentration, temperature, and mV display

Temperature sensor adjustment function

Auto Hold

Auto Stability function

Automatic power-off after 30 minutes

Remaining battery level display

Replaceable sensor

Water Resistance IP67*3
Display Custom monochrome digital LCD with backlight
Operating Environment 5 to 40°C, 85% relative humidity or less, non-condensing
Power Supply Two 3 V CR2032 coin-type lithium batteries
Battery Life Approximately 400 hours of continuous use with the backlight switched off*4
Main Material ABS resin
Dimensions and Weight W164 × H29 × D20 mm, excluding protruding parts
Approximately 50 g, excluding batteries
Included Accessories

Sodium ion sensor

Two CR2032 coin-type lithium batteries

One syringe

Instruction manual

Quick manual

Storage case

150 ppm sodium ion standard solution, 14 mL × 1 bottle

2000 ppm sodium ion standard solution, 14 mL × 1 bottle

Sampling Sheet B × 5 sheets

Main Consumables

S022: Sodium ion sensor

Y022H: 2000 ppm sodium ion standard solution

Y022L: 150 ppm sodium ion standard solution

*1 Measurement is possible from 0.05 mL when using Sampling Sheet B. Close the sensor cover during measurement. For samples containing fine particles, use a separate sampling-sheet retaining cover.

*2 Indicates repeatability when the same standard solution is measured after calibration with that standard solution. Error in the standard solution and rounding error of ±1 digit are not included.

*3 Equivalent to IP67. The meter will not fail after immersion in water at a depth of 1 m for 30 minutes. It cannot be used underwater.

*4 Battery life is reduced to approximately one-third when the backlight is used. The backlight remains illuminated for approximately 20 seconds.

Technical Measurement Notes

The displayed result represents sodium ion concentration. It is not a direct measurement of total salt or sodium chloride concentration.

Measurement values may be affected by ions other than sodium contained in the sample.

The reference pH range for the sodium ion sensor is pH 3 to 9 at a sodium concentration of 10−3 mol/L.

The stated selectivity coefficient for potassium ions (K+) and rubidium ions (Rb+) is 1 × 10−2 relative to sodium.

For quantitative comparisons, keep the sample preparation, dilution or extraction ratio, temperature, calibration procedure, and measurement conditions consistent.