HORIBA Compact Nitrate Ion Meter Kit for Crop LAQUAtwin NO3-11C

HORIBASKU: 4540565006988
No reviews

Price:
Sale price$417.00 USD

SUMMARY

The LAQUAtwin NO3-11C is a compact nitrate ion meter designed specifically for measuring nitrate concentration in crops.

Extracted crop sap can be applied directly to the flat ion-selective sensor, allowing nitrate concentration to be measured quickly from only 0.3 mL of sample.

The meter covers a wide nitrate measurement range and includes dedicated crop standard solutions and the equipment required for crop sap extraction. It is suitable for monitoring crop growth, nutrient conditions, and cultivation management in the field.

HORIBA LAQUAtwin NO3-11C compact nitrate ion meter for crops

FEATURES

  • Designed specifically for nitrate measurement in crops
  • Measures nitrate ion concentration from only 0.3 mL of crop sap
  • Measurement possible from 0.05 mL when using Sampling Sheet B, sold separately
  • Flat nitrate ion-selective sensor
  • Measures nitrate ion (NO3) and nitrate-nitrogen (NO3-N)
  • Wide nitrate measurement range from 6 to 9900 ppm
  • Dedicated 300 ppm and 5000 ppm crop standard solutions included
  • Up to two calibration points
  • Low- and high-concentration calibration points can be adjusted
  • Temperature sensor adjustment function
  • Auto Hold function
  • Auto Stability function
  • Temperature and mV measurement modes
  • Measured-value multiplication compensation
  • Backlit monochrome digital LCD
  • Automatic power-off after 30 minutes
  • Remaining battery level display
  • IP67 water-resistant construction
  • Replaceable sensor
  • Crop measurement kit and carrying case included

CROP MEASUREMENT

The included crop measurement kit provides the main equipment required to extract crop sap and apply it directly to the flat nitrate ion sensor.

Note: The appropriate sampling part and preparation method may vary depending on the crop. Keep the crop variety, sampled plant part, sample amount, extraction procedure, dilution ratio, and measurement conditions consistent when comparing results.

Prepare the Crop Sample

Collect the appropriate part of the crop and use the included crop sap press to extract sufficient liquid for measurement.

Preparing a crop sample for nitrate ion measurement

Apply the Extracted Sap

Apply the extracted crop sap directly to the flat sensor using one of the included 1 mL droppers. At least 0.3 mL is required for direct measurement.

Applying extracted crop sap to a LAQUAtwin nitrate ion sensor

Measure and Compare

Close the light shield cover and measure the nitrate concentration. For reliable comparisons, use the same sampling and preparation procedure for each measurement.

Measuring crop sap with a LAQUAtwin nitrate ion meter

INCLUDED CROP MEASUREMENT KIT

  • Five 1 mL droppers
  • One 250 mL wash bottle
  • One crop sap press
  • Three sample cups
  • Instruction manual
  • Quick manual
  • Carrying case

SPECIFICATIONS

Model LAQUAtwin-NO3-11C
Intended Use Nitrate measurement in crops
Measurement Principle Ion-selective electrode method
Required Sample Volume 0.3 mL or more
Measurement from 0.05 mL is possible when using Sampling Sheet B, sold separately*1
Measurement Range

Nitrate ion (NO3): 6 to 9900 ppm (mg/L)

Nitrate-nitrogen (NO3-N): 1.4 to 2200 ppm (mg/L)

Resolution

0 to 99 ppm: 1 ppm

100 to 990 ppm: 10 ppm

1000 to 9900 ppm: 100 ppm

Temperature Display Range / Resolution 0 to 50°C / 0.1°C
Calibration Up to 2 points
Default calibration values: 300 ppm and 5000 ppm
Accuracy ±10% of the reading*2
Main Functions

Adjustable low- and high-concentration calibration points

Multiplication compensation coefficient: 0.01 to 9.90

Concentration, temperature, and mV display modes

Temperature sensor adjustment function

Auto Hold

Auto Stability function

Automatic power-off after 30 minutes

Remaining battery level display

Replaceable sensor

Water Resistance IP67 equivalent*3
Display Custom monochrome digital LCD with backlight
Operating Environment 5 to 40°C, 85% relative humidity or less, non-condensing
Power Supply Two 3 V CR2032 coin-type lithium batteries
Battery Life Approximately 400 hours of continuous use with the backlight switched off*4
Main Material ABS resin
Dimensions and Weight W164 × H29 × D20 mm, excluding protruding parts
Approximately 50 g, excluding batteries
Included Accessories

Two CR2032 coin-type lithium batteries

300 ppm crop-specific nitrate ion standard solution, 14 mL × 1 bottle

5000 ppm crop-specific nitrate ion standard solution, 14 mL × 1 bottle

Five 1 mL droppers

One 250 mL wash bottle

One crop sap press

Three sample cups

Instruction manual

Quick manual

Carrying case

Main Consumables

S040: Nitrate ion sensor

Y041: 5000 ppm nitrate ion standard solution

Y042: 300 ppm nitrate ion standard solution

*1 Measurement is possible from 0.05 mL when using Sampling Sheet B. Sampling Sheet B is sold separately for the NO3-11C. Close the light shield cover during measurement.

*2 Indicates repeatability when the same standard solution is measured after calibration with the standard solution. Standard solution error and rounding error of ±1 digit are not included.

*3 Equivalent to IP67. The meter will not fail after immersion in water at a depth of 1 m for 30 minutes. It cannot be used underwater.

*4 Battery life is reduced to approximately one-third when the backlight is used. The backlight remains illuminated for approximately 20 seconds.

Calibration and Crop Measurement Notes

Use the dedicated 300 ppm and 5000 ppm crop-specific nitrate standard solutions supplied for the NO3-11C.

Nitrate-nitrogen (NO3-N) represents the amount of nitrogen contained in nitrate. It is not a measurement of total nitrogen.

Measurement results may be affected by ions and other substances contained in the crop sap.

If dilution or another form of sample preparation is required, keep the preparation method and dilution ratio consistent when comparing results.

For reliable comparisons, keep the crop variety, sampled plant part, growth stage, sampling time, extraction method, calibration procedure, and measurement conditions consistent.