{"product_id":"kett-infrared-moisture-analyzer-fd-660","title":"KETT Infrared Moisture Analyzer FD-660","description":"\u003cdiv class=\"product-description\"\u003e\n\u003cdiv class=\"main-column\"\u003e\n\u003cdiv class=\"detail\"\u003e\n\u003ch2\u003eSUMMARY\u003c\/h2\u003e\n\u003cp\u003eThe KETT FD-660 is a general-purpose infrared moisture analyzer that determines moisture or solid content by measuring the loss in sample weight during controlled heating and drying.\u003c\/p\u003e\n\u003cp\u003eDesigned as a reliable basic model for routine moisture testing, it can be used with a wide range of materials, including foods, chemicals, sludge, textiles, feathers, and biomass fuels.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail\"\u003e\n\u003ch2\u003eFEATURES\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable moisture and solid-content display resolution of 0.1% or 0.01%\u003c\/li\u003e\n\u003cli\u003eMass resolution of 0.005 g\u003c\/li\u003e\n\u003cli\u003eAccepts sample weights from 1 to 80 g\u003c\/li\u003e\n\u003cli\u003eAuto-tare mechanism continuously corrects the zero point to reduce balance drift during extended measurements\u003c\/li\u003e\n\u003cli\u003eOrganic carbon heaters provide efficient infrared drying\u003c\/li\u003e\n\u003cli\u003eAdjustable drying temperature from 30 to 180°C in 1°C increments\u003c\/li\u003e\n\u003cli\u003eAutomatic stop mode for ending measurement according to the drying condition\u003c\/li\u003e\n\u003cli\u003eTimed stop mode adjustable from 1 to 120 minutes\u003c\/li\u003e\n\u003cli\u003ePre Heat mode helps stabilize the instrument before measurement\u003c\/li\u003e\n\u003cli\u003eStores up to five sets of measurement conditions for different sample types\u003c\/li\u003e\n\u003cli\u003eStores up to 50 measurement results for later output\u003c\/li\u003e\n\u003cli\u003eBacklit 96 × 40 mm LCD\u003c\/li\u003e\n\u003cli\u003eRS-232C interface for connection to an optional printer or computer data-logging system\u003c\/li\u003e\n\u003cli\u003eLarge stainless-steel sample dish measuring 110 mm in diameter\u003c\/li\u003e\n\u003cli\u003eBalance calibration function\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail\"\u003e\n\u003ch2\u003eMEASUREMENT PRINCIPLE\u003c\/h2\u003e\n\u003cp\u003eThe FD-660 uses the loss-on-drying method. The sample is heated and dried by infrared radiation, and the instrument calculates moisture or solid content from the change in mass caused by moisture evaporation.\u003c\/p\u003e\n\u003cp\u003eLoss-on-drying is a fundamental gravimetric measurement method that is widely used in standard moisture-testing procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail\"\u003e\n\u003ch2\u003eORGANIC CARBON HEATER\u003c\/h2\u003e\n\u003cp\u003eThe FD-660 uses two 280 W organic carbon heaters. In the wavelength range where moisture efficiently absorbs infrared energy, the heaters provide effective sample drying.\u003c\/p\u003e\n\u003cp\u003eThe heater has a reference operating life of approximately 7,000 hours, which is about four times longer than conventional infrared lamps. This figure represents past heater performance and is not a guaranteed service life.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail\"\u003e\n\u003ch2\u003eSUITABLE SAMPLES\u003c\/h2\u003e\n\u003cp\u003eThe FD-660 can be used with materials that meet both conditions below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeating causes primarily moisture to evaporate from the sample\u003c\/li\u003e\n\u003cli\u003eHeating does not cause dangerous chemical reactions, combustion, explosion, or the release of hazardous substances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMost materials that meet these conditions can be measured. Appropriate drying temperature, sample quantity, preparation, and stopping conditions should be established for each material.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail\"\u003e\n\u003ch2\u003eSPECIFICATIONS\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFD-660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Method\u003c\/th\u003e\n\u003ctd\u003eLoss-on-drying method using heating, drying, and mass measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSample Mass\u003c\/th\u003e\n\u003ctd\u003e1 to 80 g\u003cbr\u003eVariable sample-mass method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay Resolution\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eMoisture content \/ solid content: 0.1% or 0.01%, selectable\u003csup\u003e*1\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eMass: 0.005 g\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Range\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eWet-basis moisture content: 0 to 100%\u003c\/p\u003e\n\u003cp\u003eSolid content: 0 to 100%\u003c\/p\u003e\n\u003cp\u003eDry-basis moisture content: 0 to 500%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003eStandard deviation of 0.1% with a sample mass of 5 g or more\u003csup\u003e*2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Modes\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic stop mode\u003c\/p\u003e\n\u003cp\u003eTimed stop mode: 1 to 120 minutes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature Setting Range\u003c\/th\u003e\n\u003ctd\u003e30 to 180°C in 1°C increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePreheating\u003c\/th\u003e\n\u003ctd\u003ePre Heat mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMeasurement Condition Memory\u003c\/th\u003e\n\u003ctd\u003eUp to 5 sets of measurement conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData Memory\u003c\/th\u003e\n\u003ctd\u003eUp to 50 measurement results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eBacklit LCD, 96 × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal Interface\u003c\/th\u003e\n\u003ctd\u003eRS-232C interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat Source\u003c\/th\u003e\n\u003ctd\u003eOrganic carbon heaters, 280 W × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eAC100–120 V or AC220–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Power Consumption\u003c\/th\u003e\n\u003ctd\u003e900 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eW222 × D360 × H196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSample Dish\u003c\/th\u003e\n\u003ctd\u003eStainless steel\u003cbr\u003eØ110 mm × 11 mm deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIncluded Accessories\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eStainless-steel sample dishes × 2\u003c\/p\u003e\n\u003cp\u003eSample dish tongs × 1\u003c\/p\u003e\n\u003cp\u003eWindshield × 1\u003c\/p\u003e\n\u003cp\u003eSample dish holder × 1\u003c\/p\u003e\n\u003cp\u003eSpoon × 1\u003c\/p\u003e\n\u003cp\u003eSpare fuses × 2\u003c\/p\u003e\n\u003cp\u003eAluminum foil sheets × 10\u003c\/p\u003e\n\u003cp\u003ePower cord × 1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e*1\u003c\/strong\u003e The 0.01% setting represents the displayed resolution and does not guarantee measurement accuracy to 0.01%.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*2\u003c\/strong\u003e Repeatability is based on KETT-specified measurement conditions and standard samples. Actual performance may vary depending on the sample, preparation method, sample mass, and drying conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Kett","offers":[{"title":"Default Title","offer_id":44470987849771,"sku":"FD-660","price":1930.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/7027\/2043\/files\/Kett_FD-660.jpg?v=1784857424","url":"https:\/\/japan-agritrading.com\/products\/kett-infrared-moisture-analyzer-fd-660","provider":"Japan Agri Trading","version":"1.0","type":"link"}